China | Engilsh | Russian
You are here :Products > Online UPS > SKT 3/1 10-30K LF UPS
Products
  Product lines
Solar Power/Battery
Solar Inverter
High Frequency Home Inverter
Pure sine wave Inverter
Car inverter SKI Series
Online UPS
  SKG-V1-6KVA HF UPS
  SKG 1-3K HF UPS
  SKG 6-20K HF UPS
  SKS 2-20K LF UPS
  SKT 3/1 10-30K LF UPS
  SKTT 3/3 10-160K LF UPS
  PDSP UPS
  PPS UPS
AVR
Standby/line Interactive UPS
Oscilloscope/DC Power/Switching
  Solution
Solution
SKT 3/1 10-30K LF UPS
   
SKT 3/1 10-30K LF UPS
SKT 3/1 10-30K LF UPS SKT 3/1 10-30K LF UPS SKT 3/1 10-30K LF UPS
Main Features

●Three phase in, one phase out
 
 
 
●True On-line double conversion design providing all power protection
 
●Sine wave pluse width modulation
 
 
 
●IGBT Iinverter design
 
 
 
●Wide input voltage window
 
 
 
●Pure sine wave output with less than 3% THD
 
 
 
●Expandable backup time
 
 
 
●Generator compatible
 
 
 
●Cold start
 
 
 
 
●Load/battery power meter display
 
 
 
●Overload,on-line,battery status LED+LCD
 
 
 
●Advanced Battery Management
 
 
 
●Automatically charging in UPS OFF mode
 
 
 
●Zero transfer time on AC mode to/from battery,AC mode to/from bypass
●Smart RS232 communication port
 
 
 
●Optional SNMP cards
 
 
 

  Overview

Series

SKT Series

Capacity(VA)

6KVA

8KVA

10KVA

15KVA

20KVA

25KVA

30KVA

Power(W)

4.8KW

6.4KW

8KW

12KW

16KW

20KW

24KW

Power factor

0.8

Input

Voltage Range

380V±20%(3 phase) or 190V±20%(3 phase) 

Frequency

50±5% or 60HZ±5%

Phase

3 Phase+GND

Max.Current

10A

13A

16A

24A

32A

40A

56A

Output

Phase

Single phase+GND

Voltage Range

220VAC±1% or 110VAC±1%

Frequency

50(60)HZ±1%

Waveform

Sine wave

Overload Capacity

Overload(110%-150%),20s later go bypass,auto resume when load become normal

THD

less rhan 3%(linear load)

Battery

DC Voltage

192VDC

240VDC

 

Max Charge Current

4A

6A

Efficiency

 

>85%

Transfer Time

 

0ms

Panel Indication

LCD

Input/output voltage,input/output frequency,battery voltage,load capacity

LED

Low battery,online,inverter,bypass,abnormal

Environment

Temperature

0~40℃

Humidity

0~95%(non condensing)

Noise

<58dB(1m)

Communication

Interface

RS232

Software

1.Power status 2.UPS shutdown 3.Monitor UPS status 4.UPS self test 5.Auto-save files

Other

Dimension(W×D×H)(mm)

305×585×864

740×470×1180

Packing(W×D×H)(mm)

490×790×930

 

 

950×675×1315

Net Weight(KG) W/O battery)

118

135

155

262

297

326

326

Copy right © SAKO GROUP. TEL:86-577-62666005 62666006 FAX:86-577-62666009